Toyota Camry

1996-2001 of release

Repair and car operation



Kamri's Toyota
+ 1. Maintenance instruction
+ 1.2. Information before car driving
+ 1.3. Independent maintenance
+ 1.4. Technical characteristics
+ 1.5. Some councils upon car purchase
+ 2. Maintenance
- 3. Engines
   + 3.1.2. Compression check
   + 3.2. 6-cylinder dvukhryadny engines of V6 3,0 l
   + 3.3. Partition of engines
   - 3.4. Engine electric equipment
      3.4.2. Technical characteristics
      3.4.3. Storage battery
      3.4.4. Power cables
      3.4.5. Ignition system
      3.4.6. Coil (and) ignitions
      3.4.7. Check of the moment of ignition
      3.4.8. Block of electronic ignition
      3.4.9. System of a charge of the battery
      3.4.10. Generator
      3.4.11. Tension and brush regulator
      3.4.12. System of start-up of the engine
      3.4.13. Starter electric motor
      3.4.14. Traction relay
      3.4.15. Main malfunctions of electric equipment
      3.4.16. That it is necessary to know to the owner of the car with the injector engine
      3.4.17. Turbo doctor
+ 4. Cooling system
+ 5. Heating and ventilation
+ 6. Fuel system
+ 7. Exhaust system
+ 8. Transmission
+ 9. Running gear
+ 10. Brake system
+ 11. Body
+ 12. Electric equipment


3.4.10. Generator

GENERAL INFORMATION

Generator installation on 4-cylinder engines

1. Adjusting bolt
2. Wire
3. Socket
4. Generator
5. Belt
6. Axial bolt

Generator installation on the V6 engine

1. Washer
2. Wire
3. Socket
4. Adjusting bolt
5. Generator
6. Belt
7. Lock bolt
8. Axial bolt

Removal

PERFORMANCE ORDER
1. Disconnect the battery from weight.
2. Disconnect from the wire generator.
3. Weaken axial (And), lock (In) and adjusting (C) bolts of the generator and remove a belt.
4. Turn out adjusting and axial bolts and remove the generator.
5. If you decided to replace the generator, it is necessary to mean that the new generator should accuracy correspond to the replaced. Upon purchase track that number on the case of the new unit corresponded to number replaced, and the arrangement of conclusions on both units coincided.

Installation

The generator is established upside-down.