1. Disconnect the socket (the sensor is on a partition of a motor compartment) and check existence of tension 5 In between conclusions 1 (–) and 3 (+) at the included ignition. If tension is not present, PCM – the module should hand over in repair. Figures designated conclusions of sockets of the sensor. |
2. Attach the socket and check tension existence between conclusions 2 (+) and 1 (–), having connected щупы the voltmeter to a back part of conclusions and having created in the sensor depression by the manual vacuum pump via the union (disconnect from the sensor a hose). At the included ignition tension should be the following: at pressure of 100 mm Hg 0,3–0,5 In at pressure of 200 mm Hg 0,7–0,9 In at pressure of 300 mm Hg 1,1–1,3 In at pressure of 400 mm Hg 1,5–1,9 In at pressure of 500 mm Hg of 1,9-2,1 Century. Otherwise the sensor replace. |
|